Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.739
Filtrar
1.
COPD ; 21(1): 2321379, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38655897

RESUMO

INTRODUCTION: Spirometry is the gold standard for COPD diagnosis and severity determination, but is technique-dependent, nonspecific, and requires administration by a trained healthcare professional. There is a need for a fast, reliable, and precise alternative diagnostic test. This study's aim was to use interpretable machine learning to diagnose COPD and assess severity using 75-second carbon dioxide (CO2) breath records captured with TidalSense's N-TidalTM capnometer. METHOD: For COPD diagnosis, machine learning algorithms were trained and evaluated on 294 COPD (including GOLD stages 1-4) and 705 non-COPD participants. A logistic regression model was also trained to distinguish GOLD 1 from GOLD 4 COPD with the output probability used as an index of severity. RESULTS: The best diagnostic model achieved an AUROC of 0.890, sensitivity of 0.771, specificity of 0.850 and positive predictive value (PPV) of 0.834. Evaluating performance on all test capnograms that were confidently ruled in or out yielded PPV of 0.930 and NPV of 0.890. The severity determination model yielded an AUROC of 0.980, sensitivity of 0.958, specificity of 0.961 and PPV of 0.958 in distinguishing GOLD 1 from GOLD 4. Output probabilities from the severity determination model produced a correlation of 0.71 with percentage predicted FEV1. CONCLUSION: The N-TidalTM device could be used alongside interpretable machine learning as an accurate, point-of-care diagnostic test for COPD, particularly in primary care as a rapid rule-in or rule-out test. N-TidalTM also could be effective in monitoring disease progression, providing a possible alternative to spirometry for disease monitoring.


Assuntos
Capnografia , Aprendizado de Máquina , Doença Pulmonar Obstrutiva Crônica , Índice de Gravidade de Doença , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Capnografia/métodos , Idoso , Modelos Logísticos , Sensibilidade e Especificidade , Volume Expiratório Forçado , Algoritmos , Valor Preditivo dos Testes , Área Sob a Curva , Estudos de Casos e Controles , Espirometria/instrumentação
3.
Am J Emerg Med ; 79: 85-90, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38401230

RESUMO

BACKGROUND: Several noninvasive solutions are available for the assessment of patients at risk of deterioration. Capnography, in the form of end-tidal exhaled CO2 (ETCO2) and perfusion index (PI), could provide relevant information about patient prognosis. The aim of the present project was to determine the association of ETCO2 and PI with mortality of patients admitted to the emergency department (ED). METHODS: Multicenter, prospective, cohort study of adult patients with acute disease who needed continuous monitoring in the ED. The study included two tertiary hospitals in Spain between October 2022 and June 2023. The primary outcome of the study was in-hospital mortality (all-cause). Demographics, vital signs, ETCO2 and PI were collected. RESULTS: A total of 687 patients were included in the study. The in-hospital mortality rate was 6.8%. The median age was 79 years (IQR: 69-86), and 63.3% were males. The median ETCO2 value was 30 mmHg (26-35) in survivors and 23 mmHg (16-30) in nonsurvivors (p = 0.001). For the PI, the medians were 4.7% (2.8-8.1) for survivors and 2.5% (0.98-4-4) for nonsurvivors (p < 0.001). The model that presented the best AUC was age (odds ratio (OR): 1.02 (1.00-1.05)), the respiratory rate (OR: 1.06 (1.02-1.11)), and the PI (OR: 0.83 (0.75-0.91)), with a result of 0.840 (95% CI: 0.795-0.886); the model with the respiratory rate (OR: 1.05 (1.01-1.10)), the PI (OR: 0.84 (0.76-0.93)), and the ETCO2 (no statistically significant OR), with an AUC of 0.838 (95% CI: 0.787-0.889). CONCLUSIONS: The present study showed that the PI and respiratory rate are independently associated with in-hospital mortality. Both the PI and ETCO2 are predictive parameters with improved prognostic performance compared with that of standard vital signs.


Assuntos
Dióxido de Carbono , Índice de Perfusão , Adulto , Masculino , Humanos , Idoso , Feminino , Estudos de Coortes , Estudos Prospectivos , Capnografia , Serviço Hospitalar de Emergência
4.
Crit Care Nurs Q ; 47(2): 157-162, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38419179

RESUMO

Waveform capnography is a noninvasive measurement of ventilation and perfusion commonly employed in the prehospital setting. It is easy to apply, and modern cardiac monitors are equipped with the necessary ports and capability to display results. Despite its ease of use, end-tidal CO2 monitoring has not yet achieved widespread adoption within the hospital setting. It is routinely used in the emergency department and by anesthesiologists, but its application could support ICU management in critically ill patients. Its use is routinely supported by multiple professional societies, and it has been recommended as a requirement in all cardiac arrests. Careful analysis of the waveform and expired carbon dioxide can guide therapy for patients experiencing respiratory emergencies, hemodynamic compromise, metabolic acidosis, and shock due to trauma, hypovolemia, or sepsis. Use of capnography throughout the hospital could improve patient outcomes and prevent unidentified deterioration.


Assuntos
Dióxido de Carbono , Parada Cardíaca , Humanos , Capnografia/métodos , Serviço Hospitalar de Emergência , Monitorização Fisiológica/métodos , Unidades de Terapia Intensiva
5.
BMC Pediatr ; 24(1): 149, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424493

RESUMO

BACKGROUND: Measuring arterial partial pressure of carbon dioxide (PaCO2) is crucial for proper mechanical ventilation, but the current sampling method is invasive. End-tidal carbon dioxide (EtCO2) has been used as a surrogate, which can be measured non-invasively, but its limited accuracy is due to ventilation-perfusion mismatch. This study aimed to develop a non-invasive PaCO2 estimation model using machine learning. METHODS: This retrospective observational study included pediatric patients (< 18 years) admitted to the pediatric intensive care unit of a tertiary children's hospital and received mechanical ventilation between January 2021 and June 2022. Clinical information, including mechanical ventilation parameters and laboratory test results, was used for machine learning. Linear regression, multilayer perceptron, and extreme gradient boosting were implemented. The dataset was divided into 7:3 ratios for training and testing. Model performance was assessed using the R2 value. RESULTS: We analyzed total 2,427 measurements from 32 patients. The median (interquartile range) age was 16 (12-19.5) months, and 74.1% were female. The PaCO2 and EtCO2 were 63 (50-83) mmHg and 43 (35-54) mmHg, respectively. A significant discrepancy of 19 (12-31) mmHg existed between EtCO2 and the measured PaCO2. The R2 coefficient of determination for the developed models was 0.799 for the linear regression model, 0.851 for the multilayer perceptron model, and 0.877 for the extreme gradient boosting model. The correlations with PaCO2 were higher in all three models compared to EtCO2. CONCLUSIONS: We developed machine learning models to non-invasively estimate PaCO2 in pediatric patients receiving mechanical ventilation, demonstrating acceptable performance. Further research is needed to improve reliability and external validation.


Assuntos
Dióxido de Carbono , Respiração Artificial , Feminino , Humanos , Lactente , Masculino , Capnografia/métodos , Pressão Parcial , Reprodutibilidade dos Testes
6.
Int Emerg Nurs ; 73: 101417, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38330517

RESUMO

INTRODUCTION: Various scoring systems have been developed to safely rule out the diagnosis of acute coronary syndrome. Furthermore, the efficacy of these scoring systems in predicting the risk of major adverse cardiac events (MACE) is debated. Our aim was to compare parameters such as Integrated Pulmonary Index (IPI) and End Tidal Carbon Dioxide (etCO2) measured in the emergency department with the HEART score in terms of its success in predicting the risk of major adverse cardiac events. METHOD: Patients with atypical chest pain were registered for the study by the emergency room physician. The patients were investigated regarding gender, age, background characteristics, prognostic accuracy of etCO2, IPI, MACE, and HEART scores. RESULTS: As a result of the analysis, higher HEART Score and lower etCO2 values were determined in the MACE group compared to the group without MACE. ROC analysis was performed to determine the power of IPI, HEART Score, and etCO2 to predict MACE. The findings revealed that IPI significantly predicted MACE with an AUC value of 0.737. CONCLUSION: In our study, although the highest sensitivity values in determining the risk of 30-day MACE belonged to the HEART score, etCO2 and IPI might be other parameters that could be used to determine the risk of 30-day MACE.


Assuntos
Síndrome Coronariana Aguda , Capnografia , Humanos , Medição de Risco , Valor Preditivo dos Testes , Estudos Prospectivos , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Serviço Hospitalar de Emergência
7.
J Clin Anesth ; 94: 111374, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184918

RESUMO

OBJECTIVE: The current standards of postoperative respiratory monitoring on medical-surgical floors involve spot-pulse oximetry checks every 4-8 h, which can miss the opportunity to detect prolonged hypoxia and acute hypercapnia. Continuous respiratory monitoring can recognize acute respiratory depression episodes; however, the existing evidence is limited. We sought to review the current evidence on the effectiveness of continuous pulse oximetry (CPOX) with and without capnography versus routine monitoring and their effectiveness for detecting postoperative respiratory failure, opioid-induced respiratory depression, and preventing downstream adverse events. METHODS: We performed a systematic literature search on Ovid Medline, Embase, and Cochrane Library databases for articles published between 1990 and April 2023. The study protocol was registered in Prospero (ID: 439467), and PRISMA guidelines were followed. The NIH quality assessment tool was used to assess the quality of the studies. Pooled analysis was conducted using the software R version 4.1.1 and the package meta. The stability of the results was assessed using sensitivity analysis. DESIGN: Systematic Review and Meta-Analysis. SETTING: Postoperative recovery area. PATIENTS: 56,538 patients, ASA class II to IV, non-invasive respiratory monitoring, and post-operative respiratory depression. INTERVENTIONS: Continuous pulse oximetry with or without capnography versus routine monitoring. MEASUREMENTS: Respiratory rate, oxygen saturation, adverse events, and rescue events. RESULTS: 23 studies (17 examined CPOX without capnography and 5 examined CPOX with capnography) were included in this systematic review. CPOX was better at recognizing desaturation (SpO2 < 90%) OR: 11.94 (95% CI: 6.85, 20.82; p < 0.01) compared to standard monitoring. No significant differences were reported for ICU transfer, reintubation, and non-invasive ventilation between the two groups. CONCLUSIONS: Oxygen desaturation was the only outcome better detected with CPOX in postoperative patients in hospital wards. These comparisons were limited by the small number of studies that could be pooled for each outcome and the heterogeneity between the studies.


Assuntos
Analgésicos Opioides , Insuficiência Respiratória , Humanos , Analgésicos Opioides/efeitos adversos , Taxa Respiratória , Capnografia/métodos , Monitorização Fisiológica/métodos , Insuficiência Respiratória/induzido quimicamente , Insuficiência Respiratória/prevenção & controle , Insuficiência Respiratória/diagnóstico , Oximetria/métodos , Complicações Pós-Operatórias/diagnóstico , Hospitais
8.
Anesth Analg ; 138(3): 607-615, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37319022

RESUMO

BACKGROUND: Changes in arterial partial pressure of carbon dioxide (Pa co2 ) may alter cerebral perfusion in critically ill patients with acute brain injury. Consequently, international guidelines recommend normocapnia in mechanically ventilated patients with acute brain injury. The measurement of end-tidal capnography (Et co2 ) allows its approximation. Our objective was to report the agreement between trends in Et co2 and Pa co2 during mechanical ventilation in patients with acute brain injury. METHODS: Retrospective monocenter study was conducted for 2 years. Critically ill patients with acute brain injury who required mechanical ventilation with continuous Et co2 monitoring and with 2 or more arterial gas were included. The agreement was evaluated according to the Bland and Altman analysis for repeated measurements with calculation of bias, and upper and lower limits of agreement. The directional concordance rate of changes between Et co2 and Pa co2 was evaluated with a 4-quadrant plot. A polar plot analysis was performed using the Critchley methods. RESULTS: We analyzed the data of 255 patients with a total of 3923 paired ΔEt co2 and ΔPa co2 (9 values per patient in median). Mean bias by Bland and Altman analysis was -8.1 (95 CI, -7.9 to -8.3) mm Hg. The directional concordance rate between Et co2 and Pa co2 was 55.8%. The mean radial bias by polar plot analysis was -4.4° (95% CI, -5.5 to -3.3) with radial limit of agreement (LOA) of ±62.8° with radial LOA 95% CI of ±1.9°. CONCLUSIONS: Our results question the performance of trending ability of Et co2 to track changes in Pa co2 in a population of critically ill patients with acute brain injury. Changes in Et co2 largely failed to follow changes in Pa co2 in both direction (ie, low concordance rate) and magnitude (ie, large radial LOA). These results need to be confirmed in prospective studies to minimize the risk of bias.


Assuntos
Lesões Encefálicas , Dióxido de Carbono , Humanos , Capnografia/métodos , Estudos Retrospectivos , Respiração Artificial , Estudos Prospectivos , Pressão Parcial , Estado Terminal , Lesões Encefálicas/diagnóstico , Lesões Encefálicas/terapia
9.
J Clin Monit Comput ; 38(1): 77-88, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37792139

RESUMO

PURPOSE: Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. METHODS: The respiratory rate of intensive care unit patients was simultaneously measured using a microwave Doppler sensor, capnography, thoracic impedance pneumography, and a piezoelectric sensor beneath the mattress. Bias and 95% limits of agreement between the respiratory rate measured using capnography (standard reference) and that measured using the other three methods were calculated using Bland-Altman analysis for repeated measures. Clarke error grid (CEG) analysis evaluated the sensor's ability to assist in correct clinical decision-making. RESULTS: Eighteen participants were included, and 2,307 data points were analyzed. The bias values (95% limits of agreement) of the microwave Doppler sensor, thoracic impedance pneumography, and piezoelectric sensor were 0.2 (- 4.8 to 5.2), 1.5 (- 4.4 to 7.4), and 0.4 (- 4.0 to 4.8) breaths per minute, respectively. Clinical decisions evaluated using CEG analyses were correct 98.1% of the time for the microwave Doppler sensor, which was similar to the performance of the other devices. CONCLUSION: The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low. TRIAL REGISTRATION NUMBER: UMIN000038900, February 1, 2020.


Assuntos
Micro-Ondas , Taxa Respiratória , Humanos , Reprodutibilidade dos Testes , Monitorização Fisiológica/métodos , Capnografia/métodos
10.
Can J Anaesth ; 71(1): 95-106, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37914969

RESUMO

PURPOSE: Lack of access to safe and affordable anesthesia and monitoring equipment may contribute to higher rates of morbidity and mortality in low- and middle-income countries (LMICs). While capnography is standard in high-income countries, use in LMICs is not well studied. We evaluated the association of capnography use with patient and procedure-related characteristics, as well as the association of capnography use and mortality in a cohort of patients from Kenya and Ethiopia. METHODS: For this retrospective observational study, we used historical cohort data from Kenya and Ethiopia from 2014 to 2020. Logistic regression was used to study the association of capnography use (primary outcome) with patient/procedure factors, and the adjusted association of intraoperative, 24-hr, and seven-day mortality (secondary outcomes) with capnography use. RESULTS: A total of 61,792 anesthetic cases were included in this study. Tertiary or secondary hospital type (compared with primary) was strongly associated with use of capnography (odds ratio [OR], 6.27; 95% confidence interval [CI], 5.67 to 6.93 and OR, 6.88; 95% CI, 6.40 to 7.40, respectively), as was general (vs regional) anesthesia (OR, 4.83; 95% CI, 4.41 to 5.28). Capnography use was significantly associated with lower odds of intraoperative mortality in patients who underwent general anesthesia (OR, 0.31; 95% CI, 0.17 to 0.48). Nevertheless, fully-adjusted models for 24-hr and seven-day mortality showed no evidence of association with capnography. CONCLUSION: Capnography use in LMICs is substantially lower compared with other standard anesthesia monitors. Capnography was used at higher rates in tertiary centres and with patients undergoing general anesthesia. While this study revealed decreased odds of intraoperative mortality with capnography use, further studies need to confirm these findings.


RéSUMé: OBJECTIF: Le manque d'accès à des équipements d'anesthésie et de monitorage sécuritaires et abordables peut contribuer à des taux plus élevés de morbidité et de mortalité dans les pays à revenu faible et intermédiaire (PRFI). Alors que la capnographie est une modalité standard dans les pays à revenu élevé, son utilisation dans les PRFI n'est pas bien étudiée. Nous avons évalué l'association de l'utilisation de la capnographie avec les caractéristiques des patient·es et des interventions, ainsi que l'association de l'utilisation de la capnographie et de la mortalité dans une cohorte de patient·es du Kenya et d'Éthiopie. MéTHODE: Pour cette étude observationnelle rétrospective, nous avons utilisé des données de cohortes historiques du Kenya et de l'Éthiopie de 2014 à 2020. Une régression logistique a été utilisée pour étudier l'association entre l'utilisation de la capnographie (critère d'évaluation principal) et les facteurs patient·es/interventions, ainsi que pour étudier l'association ajustée entre la mortalité peropératoire, à 24 h et à sept jours (critères d'évaluation secondaires) et l'utilisation de la capnographie. RéSULTATS: Au total, 61 792 cas d'anesthésie ont été inclus dans cette étude. Le type d'hôpital tertiaire ou secondaire (par rapport à un établissement primaire) était fortement associé à l'utilisation de la capnographie (rapport de cotes [RC], 6,27; intervalle de confiance [IC] à 95 %, 5,67 à 6,93 et RC, 6,88; IC 95 %, 6,40 à 7,40, respectivement), tout comme l'était l'anesthésie générale (vs régionale) (RC, 4,83; IC 95 %, 4,41 à 5,28). L'utilisation de la capnographie était significativement associée à une probabilité plus faible de mortalité peropératoire chez les patient·es ayant reçu une anesthésie générale (RC, 0,31; IC 95 %, 0,17 à 0,48). Néanmoins, les modèles entièrement ajustés pour la mortalité à 24 heures et à sept jours n'ont montré aucune donnée probante d'association avec la capnographie. CONCLUSION: L'utilisation de la capnographie dans les PRFI est considérablement moins répandue que celle d'autres moniteurs d'anesthésie standard. La capnographie a été utilisée à des taux plus élevés dans les centres tertiaires et chez des patient·es sous anesthésie générale. Bien que cette étude ait révélé une diminution de la probabilité de mortalité peropératoire avec l'utilisation de la capnographie, d'autres études doivent confirmer ces résultats.


Assuntos
Anestesia por Condução , Capnografia , Humanos , Capnografia/métodos , Etiópia , Quênia , Anestesia Geral
11.
Respir Physiol Neurobiol ; 320: 104199, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38000708

RESUMO

PURPOSE: To investigate the correlation between volume of carbon dioxide elimination (V̇CO2) and end-tidal carbon dioxide (PETCO2) with cardiac output (CO) in a swine pediatric acute respiratory distress syndrome (ARDS) model. METHODS: Respiratory and hemodynamic variables were collected from twenty-six mechanically ventilated juvenile pigs under general anesthesia before and after inducing ARDS, using oleic acid infusion. RESULTS: Prior to ARDS induction, mean (SD) CO, V̇CO2, PETCO2, and dead space to tidal volume ratio (Vd/Vt) were 4.16 (1.10) L/min, 103.69 (18.06) ml/min, 40.72 (3.88) mmHg and 0.25 (0.09) respectively. Partial correlation coefficients between average CO, V̇CO2, and PETCO2 were 0.44 (95% confidence interval: 0.18-0.69) and 0.50 (0.18-0.74), respectively. After ARDS induction, mean CO, V̇CO2, PETCO2, and Vd/Vt were 3.33 (0.97) L/min, 113.71 (22.97) ml/min, 50.17 (9.73) mmHg and 0.40 (0.08). Partial correlations between CO and V̇CO2 was 0.01 (-0.31 to 0.37) and between CO and PETCO2 was 0.35 (-0.002 to 0.65). CONCLUSION: ARDS may limit the utility of volumetric capnography to monitor CO.


Assuntos
Dióxido de Carbono , Síndrome do Desconforto Respiratório , Humanos , Criança , Animais , Suínos , Volume de Ventilação Pulmonar , Débito Cardíaco , Capnografia , Respiração Artificial
12.
Am J Vet Res ; 85(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37857347

RESUMO

OBJECTIVE: To evaluate the agreement between the Tafonius large animal ventilator-integrated volumetric capnography (vCap) software and the Respironics NICO noninvasive cardiac output monitor reference system. ANIMALS: Data were collected from 56 healthy adult horses undergoing general anesthesia. METHODS: Animals were placed under general anesthesia and connected to the Tafonius large animal ventilator circle system. A flow partitioning device with CO2 and flow sensors was utilized to couple the endotracheal tube to the NICO monitor. Tafonius CO2 and flow sensors are incorporated into the Y-piece of the breathing circuit. Arterial blood samples were collected to determine the partial pressure of arterial carbon dioxide (PaCO2) immediately before data collection. The PaCO2 was input into the Tafonius and NICO monitor, and dead space ventilation (%Vd), end-tidal CO2 partial pressure (ETco2), mixed-expired CO2 partial pressure (Peco2), and expired tidal volume (Vt) were calculated over a single breath. Multiple measurements were completed for each patient, with a total of 200 paired data points collected for analysis. Data were assessed for normality, and Bland-Altman analysis was performed. Bias and 95% limits of agreement were calculated. RESULTS: The limits of agreement for %Vd of the ventilator-derived measurements fell within ± 10% of the NICO monitor reference method. CLINICAL RELEVANCE: Our results indicate that, when compared to the NICO monitor method, the Tafonius-integrated vCap software provides clinically acceptable values of Peco2, Vt, and %Vd in healthy adult horses.


Assuntos
Capnografia , Dióxido de Carbono , Cavalos , Animais , Capnografia/veterinária , Capnografia/métodos , Espaço Morto Respiratório/fisiologia , Volume de Ventilação Pulmonar , Respiração Artificial/veterinária , Ventiladores Mecânicos
14.
J Clin Monit Comput ; 38(2): 463-467, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38150123

RESUMO

Persistent pulmonary hypertension of the newborn (PPHN) can be monitored theoretically by the difference of the partial pressure of arterial (PaCO2) to end-tidal CO2 (EtCO2). We aimed to test the hypothesis that the PaCO2-EtCO2 gradient in infants with PPHN would be higher compared to infants without PPHN. Prospective, observational study of term-born ventilated infants with echocardiographically-confirmed PPHN with right-to-left shunting and term-born control infants without respiratory disease. The PaCO2-EtCO2 gradient was calculated as the difference between the PaCO2 measured from indwelling arterial sample lines and EtCO2 measured by continuous Microstream sidestream capnography. Twenty infants (9 with PPHN and 11 controls) were studied with a median (IQR) gestational age of 39.5 (38.7-40.4) weeks, a birthweight of 3.56 (3.15-3.93) kg and a birthweight z-score of 0.03 (- 0.91 to 1.08). The PaCO2-EtCO2 gradient was larger in the infants with PPHN compared to those without PPHN after adjusting for differences in the mean airway pressure and fraction of inspired oxygen (adjusted p = 0.037). In the infants with PPHN the median PaCO2-EtCO2 gradient decreased from 10.7 mmHg during the acute illness to 3.3 mmHg pre-extubation. The median difference in the gradient was significantly higher in infants with PPHN (6.2 mmHg) compared to infants without PPHN (-3.2 mmHg, p = 0.022). The PaCO2-EtCO2 gradient was higher in infants with PPHN compared to term born infants without PPHN and decreased over the first week of life in infants with PPHN. The gradient might be utilised to monitor the evolution and resolution of PPHN.


Assuntos
Dióxido de Carbono , Hipertensão Pulmonar , Recém-Nascido , Lactente , Humanos , Estudos Prospectivos , Peso ao Nascer , Respiração Artificial , Capnografia , Volume de Ventilação Pulmonar
15.
Diving Hyperb Med ; 53(4): 327-332, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38091592

RESUMO

Introduction: Capnography aids assessment of the adequacy of mechanical patient ventilation. Physical and physiological changes in hyperbaric environments create ventilation challenges which make end-tidal carbon dioxide (ETCO2) measurement particularly important. However, obtaining accurate capnography in hyperbaric environments is widely considered difficult. This study investigated the EMMA capnograph for hyperbaric use. Methods: We compared the EMMA capnograph to sidestream capnography and the gold standard arterial carbon dioxide blood gas analysis in a hyperbaric chamber. In 12 resting subjects breathing air at 284 kPa, we recorded ETCO2 readings simultaneously derived from the EMMA and sidestream capnographs during two series of five breaths (total 24 measurements). An arterial blood gas sample was also taken simultaneously in five participants. Results: Across all measurements there was a difference of about 0.1 kPa between the EMMA and sidestream capnographs indicating a very slight over-estimation of ETCO2 by the EMMA capnograph, but fundamentally good agreement between the two end-tidal measurement methods. Compared to arterial blood gas pressure the non-significant difference was about 0.3 and 0.4 kPa for the EMMA and sidestream capnographs respectively. Conclusions: In this study, the EMMA capnograph performed equally to the sidestream capnograph when compared directly, and both capnography measures gave clinically acceptable estimates of arterial PCO2.


Assuntos
Capnografia , Dióxido de Carbono , Humanos , Capnografia/métodos , Respiração , Respiração Artificial , Gasometria
16.
Artigo em Inglês | MEDLINE | ID: mdl-38083576

RESUMO

Volumetric capnography (VCap) provides information about CO2 exhaled per breath (VCO2br) and physiologic dead space (VDphys). A novel wireless device with a high response time CO2 mainstream sensor coupled with a digital flowmeter was designed to monitor all VCap parameters online in rabbits (SAMAY S24).Ten New Zealand rabbits were anesthetized and mechanically ventilated. VCO2br corresponds to the area under the VCap curve. We used the modified Langley method to assess the airway VD (VDaw) and the alveolar CO2 pressure. VDphys was estimated using Bohr's formula, and the alveolar VD was calculated by subtracting VDaw from VDphys. We compared (Bland-Altman) the critical VCap parameters obtained by SAMAY S24 (Langley) with the Functional Approximation based on the Levenberg-Marquardt Algorithm (FA-LMA) approach during closed and opened chest conditions.SAMAY S24 could assess dead space volumes and VCap shape in real time with similar accuracy and precision compared to the 'offline' FA-LMA approach. The opened chest condition impaired CO2 kinetics, decreasing the phase II slope, which was correlated with the volume of CO2 exhaled per minute.


Assuntos
Capnografia , Dióxido de Carbono , Animais , Coelhos , Capnografia/métodos , Espaço Morto Respiratório/fisiologia , Pulmão , Algoritmos
17.
Rev. esp. anestesiol. reanim ; 70(10): 602-607, Dic. 2023. ilus
Artigo em Espanhol | IBECS | ID: ibc-228138

RESUMO

El lavado pulmonar total (LPT) es la principal terapia para la proteinosis alveolar pulmonar (PAP). Formulamos la hipótesis de la aplicabilidad de la ecografía pulmonar (EP) para guiar el alcance de la inundación alveolar en un varón de 15 años. El LPT de cada pulmón consistió en la instilación de solución salina, seguida de quinesioterapia y drenaje de líquidos. En el primer LPT, el proceso se repitió hasta observar el aclaramiento macroscópico progresivo del líquido de lavado, con visualización simultánea de las fases de aireación pulmonar mediante EP. En la segunda etapa, se utilizó un patrón de EP para guiar la extensión del lavado. La aparición del patrón de tipo tisular mediante broncograma del fluido definió la terminación temprana de la infusión salina. En conclusión, la EP contribuyó a monitorizar las fases de la desaireación pulmonar a lo largo del LPT, y redujo la cantidad total de solución salina instilada, con el fin de minimizar sus complicaciones inherentes.(AU)


Whole lung lavage (WLL) is the first-line treatment for pulmonary alveolar proteinosis. We hypothesized that lung ultrasound (LUS) would guide flooding during treatment in a 15-year-old boy. WLL of each lung consisted of instillation of saline followed by kinesiotherapy and fluid drainage. In the first WLL, the lung was repeatedly flooded until the lavage fluid was clear on macroscopic examination. During this process, LUS was used to visualise lung aeration. In the second WLL, we used LUS signs to guide the lavage volume. The appearance of the fluid bronchogram sign showed that saline infusion could be stopped earlier than in the first lavage. In conclusion, LUS helped monitor the different stages of controlled lung de-aeration during WLL and reduce the total amount of saline used. This technique will also reduce the risk of WLL-related complications.(AU)


Assuntos
Humanos , Masculino , Adolescente , Lavagem Broncoalveolar/métodos , Proteinose Alveolar Pulmonar/diagnóstico por imagem , Anestesia , Anestesia Geral/métodos , Eletrocardiografia , Capnografia , Pacientes Internados , Exame Físico , Avaliação de Sintomas , Pediatria , Líquido da Lavagem Broncoalveolar
18.
PLoS One ; 18(10): e0292667, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37871102

RESUMO

OBJECTIVE: To determine the diagnostic accuracy of end-tidal carbon dioxide (ETCO2) detection using capnography for verifying the correct placement of nasogastric tubes (NGTs) among adult patients in hospital settings. MATERIALS AND METHODS: A prospective observational diagnostic study will be conducted. Patients ≥ 18-year-old and requiring the insertion of an NGT will be recruited using a convenience sampling method from 39 general medical and geriatric wards, intensive care units, accident and emergency departments, and subacute/rehabilitation/infirmary wards in 21 acute or subacute/convalescent/extended care hospitals. ETCO2 detection by sidestream capnography, which indicates an airway intubation of an NGT when a capnogram waveform or an ETCO2 level > 10mmHg (1.33 kPa) occurs, will serve as the index test. The reference standards will be the X-ray performed and pH value of gastric aspiration (pH ≤ 5.5) after the index test. Each participant will be included only once. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve of capnography will be calculated to assess the diagnostic performance of capnography. The variability in diagnostic accuracy in participants with different characteristics will be explored by using chi-squared or Fisher's exact tests. The time spent and the cost of the tests will be compared using the paired t-test. All statistical tests will be two-sided with a level of significance set at 0.05. DISCUSSION: This study will provide evidence on the diagnostic accuracy of capnography in verifying NGT placement and its applicability to patients in hospitals settings, since this evidence is limited in the current literature. In addition, it will help identify the optimal combination of tests in verifying the correct placement of NGTs and inform the update of clinical practice guidelines and stakeholders' decisions on the adoption of ETCO2 detection as a routine method for verifying NGT placement. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT05817864.


Assuntos
Capnografia , Dióxido de Carbono , Humanos , Adulto , Idoso , Adolescente , Capnografia/métodos , Intubação Gastrointestinal/métodos , Hospitais , Unidades de Terapia Intensiva , Estudos Observacionais como Assunto
20.
Anesth Analg ; 137(5): 921, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862389
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...